SUMMIT split type RH-A100-OMS-820 3000 5000kg mounting on multi cable steel elevator force tension load weighing control device
Mounting on multiple-rope elevator load weighing control device
OMS-820-RH-A300
Description:
The multiple wire rope clamping load weighing device RH-A-OMS-820 consists of one rope tension sensor RH-A and a control unit OMS-820, and the rope sensor is available for mounting to cables between 8mm and 16mm in diameter, and clamp on multiple ropes from 2-10 pcs rope depending on the rope space, diameter and so on. This solution covers the wide load range f 500 to 4500kg per cable(roping 1:1), .calibration is auto-matic and no test weights are required. It's perfect for modernization as well as for new installations.
Features:
- High sensitivity for rope sensors
- Clamp on the multiple wire ropes
- Suitable for wire ropes from 8 to 16 mm diameter.
- Separate type installation and easy maintenance
- Fast and easy installation, especially ideal for modernization
- Operating capacity up to 5000 kg
- Protection with broken and loose rope alarm function output
- High sensitivity for rope sensors
- Adjustable for different ropes - thickness (8-16mm)
- More suitable for elevator retrofit
Wire rope tension load sensor : |
RH-A100 |
RH-A200 |
RH-A300 |
Operation capacity |
3000kg |
3000kg |
5000kg |
Wire rope diameter |
8-16mm |
8-16mm |
8-16mm |
Sensitivity |
2.0±0.02%mV/V |
2.0±0.02%mV/V |
2.0±0.02%mV/V |
Excitation voltage |
5-12VDC |
5-12VDC |
5-12VDC |
Input impedance |
760±10Ω |
760±10Ω |
760±10Ω |
Output impedance |
700±2Ω |
700±2Ω |
700±2Ω |
Insulation impedance |
≥5000MΩ |
≥5000MΩ |
≥5000MΩ |
Safe overload ratio |
150%F.S |
150%F.S |
150%F.S |
Ultimate overload |
200% F.S |
200% F.S |
200% F.S |
Total error |
±0.5%F.S |
±0.5%F.S |
±0.5%F.S |
Material |
Aluminum alloy |
Aluminum alloy |
Aluminum alloy |
Creep error |
±0.02% F.S. |
±0.02% F.S. |
±0.02% F.S. |
TC SPAN |
±0.02%F.S/10ºC |
±0.02%F.S/10ºC |
±0.02%F.S/10ºC |
Working temperature |
-30ºC~+70ºC |
-30ºC~+70ºC |
-30ºC~+70ºC |
Protection class |
IP68 |
IP68 |
IP68 |
Cable length |
2.5m |
2.5m |
2.5m |
Elevator Campled on multiple ropes tension load cells RH-A seirs Size:
Elevator weighing control unit OMS-820 technical Parameters:
Control Unit:OMS-820 |
Operation Voltage |
AC/DC16-48V |
Nominal power |
4W |
Load Cell Channel number |
2 pcs |
Relay Number |
6(overload,full,half, empty,rope loose,rope deviation) |
Contact Load |
1A 125VAC, 2A 30VDC,5A250VAC,5A 30VDC |
Display Type |
4 digits 0.36inch LED |
Display mode |
Weight/percentage |
Key Number |
6pcs |
Voltage Analog |
-10V-+10,0V-+10V |
Current Analog |
Optional(4-20mA) |
Sensor operation voltage |
DC5V |
Signal Hold Voltage |
AC/DC12-230V |
Measuring precision |
0.1% |
Operation temperature |
-45degree-+85degree |
Size |
90x84x58mm |
Weight |
260g |
Instllation &Wiring Diagram

A wide variety ofInstallation options of load sensors on lift
The following installation options are available for the load sensors:
› RHP-X strain link Sensor on car frame
› Multi rope sensor on car after rope clamps ‚
› RH series load sensor on fixed point of individual rope attachment
› UC-AP sensor under elevator car floor …