SUMMIT UC-H-B with out squeeze head Rated load 1200 3000kg at elevator rope hitch attachment compression load transducer
UC-H(B) with squeeze head UC-Hwithout squeez head
Description:
The installation of the load weighing sensor UC-H series is made normally for new installations, given the complexity of its positioning. Although it is the most complex to install, it is the most precise,since we make a scale of the cabin, where there is no influence of external mechanical agents, as the guides or the compensation chain. This cabin compression over Load cell UC-H comes with Anti vibration rubber pad mounting & this provides Dampening effect. And if the anti vibration rubber(squeeze head) is removed, it is a good way to install at the wire rope attachment or between the wire rope hitch plates, and it is more flexible, and can meed requests for different installation position.
Features:
- Compression Load cell specially designed for the Installation under cabin
- (placed in the center)
- quipped with silent-block pad to avoid the transfer of vibrations.
- It can be connected to any unit control on the Series OMS-560,OMS-520,OMS-820, except OMS-620S and OMS-920S
- Under cab sensors are not recommended for modernization
- Various installation installation
- Perfect for new installations
- Load cell for installation under elevator cabin.
- Mounted on a silent-block pad that avoids the transfer of vibrations .
- Adjustable locking screw to adjust the unevenness of the bottom of the car during assembly
Model |
UC-H(B) with squeeze head |
UC-H |
Rated Load |
1200kg/3000kg |
1200kg/3000kg |
Sensitivity |
2.0+-0.02%mv/v |
2.0+-0.02%mv/v |
Total error |
+/-0.5% F.S |
+/-0.5% F.S |
Excitation |
5-12V DC |
5-12V DC |
Creep Error |
+/-0.02% F.S |
+/-0.02% F.S |
Insulation Impedance |
≥5000 Ohm |
≥5000 Ohm |
T C SPAN |
+/-0.02% F.S./10ºC |
+/-0.02% F.S./10 ºC |
Operation temperature range |
-30 to 70 degree Celsius |
-30 to 70 degree Celsius |
Input Resistance |
760+/-10 ohm |
760+/-10 ohm |
Output Resistance |
700+/-2 ohm |
700+/-2 ohm |
Safe Overload |
150% F.S. |
150% F.S. |
Ultimate Overload |
200% F.S. |
200% F.S. |
Construction |
Alloy Steel |
Alloy Steel |
Protection Class |
IP68 |
IP68 |
Cable Length |
8M |
8M |
Car load cell UC-H size:
Instllation &Wiring Diagram
Mount under the car floor UC-H(B) with rubber head(squeeze head)

Mount between rope hitch plate with rubber head(without squeeze head)
Installation options of load sensors on lift
The following installation options are available for the load sensors:
› RHP-X strain link Sensor on car frame
› RH-A Multi rope sensor on car after rope clamps ‚
› RH series load sensor on fixed point of individual rope attachment
› UC-AP sensor on drive frame …